Summary

Information und configuration hints for SIP provider Tele2 (Austria).


Information

General information

The Tele2 SIP Connect trunk is a SIP trunk with user authentication. You have received information about UserID, UserName and UserPassword, whereas the nameing may differ, or you have only received UserName and -password. In this case, UserID and UserName are identical.

Using a Swyx UC system may be announced when ordering the SIP Connect trunk or adjusted later via support. The Tele2 settings will then match exactly to the provider profile in SwyxWare.

Configuration

For your convenience the generated CustomProviderProfiles.config is available for download at the end of this article. Extended information about how to use this file can be found at Configuration and Adaptation of SIP Providers via Provider Profiles (kb3436).

During creation of the SIP Trunkgroup, profile 'Tele2 (AT)' has to be selected.

Important: From SwyxWare 11.00.0.0 on, the provider profile for Tele2 is already available in the list of provider profiles and the CustomProviderProfiles.config is no longer necessary.

Session Interval

The Provider Tele2 expects a session interval of 1800s for outgoing calls. Therefore create the following registry keys and set them to 1800.

Pfad (64-bit): HKLM\Software\Wow6432Node\Swyx\LinkMgr\CurrentVersion\Options

Name: SipMinSessionTimerIntervalSeconds, Typ: DWORD, Wert: 1800 (dezimal)

Name: SipSessionTimerIntervalSeconds, Typ: DWORD, Wert: 1800 (dezimal)

After these keys are created, the service 'LinkMgr' must be restarted.

Important: These registry keys will affect all SIP trunks.

SIP URIs

In order to assign incoming calls to the correct trunk, it is necessary to configure a SIP URI for the trunk. The assigned number block and the numberformat must be considered.

Example
Numberblock: +43 1 1234560 ... +43 1 1234569
In this case, the SIP URI must be entered in the format +431123456*@*.
Afterwards, the LinkMgr service has to be restarted.

Tested Features

  • Incoming/outgoing national calls
  • Incoming/outgoing international calls
  • Correct Calling Line Identification (CLI) on national and international calls
  • Holding and retrieving calls
  • Toggeling between two calls
  • Call transfer
  • Conferencing
  • Mutually supported codec:
    • G.711a
  • Incoming/outgoing DTMF signaling in accordance with via RFC2833
  • FAX transmission via T.38

Limitations

  • None

Tests:
26/07/2017 with SwyxWare 2015 R40.3.0

Overview of tested SIP provider


Links

As far as software supplied or used by us, includes open source elements the additional terms under https://www.swyx.com/open-source apply in addition. An overview which products from the Swyx portfolio include open source elements and which open source license is relevant can be found under https://www.swyx.com/open-source.

The third-party contact information included in this article is provided to help you find the technical support you need. This contact information is subject to change without notice. Swyx in no way guarantees the accuracy of this third-party contact information nor is responsible for it's content.


Comment

Comment on this article



If we have any follow-up questions, where can we contact you?

E-Mail Address (optional)


Note

This feedback form can't be used for support requests. Those requests must be directed to your Swyx reseller or distributor.