Swyx Knowledgebase
HOWTO: SX2 DualPRI V2 ISDN board configuration (kb3164)
The information in this article applies to:
- SX2 DualPRI V2
[ Summary | Information | Links ]
Summary
Summary
The ISDN board SX2 DualPRI V2 needs to be configured before first use. This article gives an overview about the possible configurations.
Information
Information
Before the SX2 DualPRI V2 card is installed into the machine you have to configure the RJ-45 socket pinout and the line termination.
The following description assumes you have the card in front of you with the RJ-45 sockets on the left side and the PCI connector pointing in your direction. Each RJ-45 socket has two jumper blocks assigned. Throughout this description the jumper block containing 2 jumpers is named JB2 and that one containing 5 jumpers is named JB5. A suffix L,R.U or D means that either all jumpers are on the block's left side (L), the right side (R), the upper side (U) or the down side (D), e.g. JB5L means that all jumpers of JB5 are jumpered to the left side.
RJ-45 Socket Pinout
The RJ-45 socket pinout can be changed with jumper blocks JB2 and JB5. It is possible to chose out of 4 different pinouts:
| Jumper Block Assignment | RJ-45 Socket Pinout |
| JB2U and JB5R |
Pin1 = TX+ Pin2 = TX- Pin4 = RX+ Pin5 = RX- |
| JB2D and JB5R |
Pin3 = TX+ Pin6 = TX- Pin4 = RX+ Pin5 = RX- |
| JB2U and JB5L |
Pin1 = RX+ Pin2 = RX- Pin4 = TX+ Pin5 = TX- |
| JB2D and JB5L |
Pin3 = RX+ Pin6 = RX- Pin4 = TX+ Pin5 = TX- |
Configuration Line Termination
On the right side beneath the jumper blocks you'll find a DIP switch with two pins. This switch is used to select the line termination. If both pins are "OFF" then no termination is present. If the left pin is "OFF" and the right pin is "ON" a 120 Ohm termination is active. If the left pin is "ON" and the right pin is "OFF" a 75 Ohm termination is active.
PCI-bus power settings
On the board's lower right side you see a jumper with three pins. Make sure that the jumper is set to position "3V3 reg".
SwyxStandby Support
The board supports the SwyxWare Option SwyxStandby. To activate support for this feature make sure that the jumper between both RJ-45 sockets is plugged in.
Board number configuration
The board number can be set with the four DIP switches located at the upper middle side of the board. The DIP switch on the left is associated to Port 1, the DIP switch on the right is associate to Port 2. The following assignment is valid:
| Switch 4 | Switch 3 | Switch 2 | Switch 1 | board number |
| off | off | off | on | 1 |
| off | off | on | off | 2 |
| off | off | on | on | 3 |
| off | on | off | off | 4 |
| off | on | off | on | 5 |
| off | on | on | off | 6 |
| off | on | on | on | 7 |
| on | off | off | off | 8 |
| on | off | off | on | 9 |
| on | off | on | off | 10 |
| on | off | on | on | 11 |
| on | on | off | off | 12 |
| on | on | off | on | 13 |
| on | on | on | off | 14 |
| on | on | on | on | 15 |
| off | off | off | off | automatic |
Please note that you have to use the numering shown in the picture rather than the numbering on the DIP-switch itself.
Please make sure that you either assign a board number for all boards in the system or configure all boards for automatic number assignment.
PCM bus connection
The board provides two connectors with 20 pins each. Those connectors are used to connect two boards with an optional PCM cable. The upper connector is the output and the lower connector is the input. Connect two boards with a PCM cable by connecting the output of the first board with the input of the second board.
LED Status Monitoring
Each E1 socket has assigned 4 monochrome LEDs as a status monitoring facility.
The following assignment is valid:
| LED1 off: | Layer 1 de-activated |
| LED1 red: | Layer 1 activated |
| LED2 green: | Layer 2 activated |
| LED3 green blinking: | At least one connection active |
| red blinking: | The line is being configured |
References
Links
- SX2 DualPRI (V2) Quickstart (English)
QR_SX2_DualPRI_en.pdf - SX2 DualPRI (V2) Quickstart (German)
QR_SX2_DualPRI_de.pdf
The third-party contact information included in this article is provided to help you find the technical support you need. This contact information is subject to change without notice. Swyx in no way guarantees the accuracy of this third-party contact information nor is responsible for it's content.
Updates
Created: 24.08.2006, Last Modified: 18.05.2007
- 25.08.2006: Target audience broadened
- 25.08.2006: Pictures added
- 13.09.2006: Added Quickstart
- 27.09.2006: Added Quickstart (English).
- 16.02.2007: Added note for board numbering.
- 18.05.2007: Board number description independent from DIP-switch placement