INFO: SwyxWare v4.33 Hotfix 13 (kb3079)
The information in this article applies to:
- SwyxWare CD v4.33
- SwyxWare v4.33
[ Summary | Information | Links ]
SummarySummary
Swyx releases the SwyxWare v4.33 Hotfix 13.
Please note the common hints on hotfixes in the following Knowledgebase article:
InformationInformation
This hotfix 13 contains also the previous hotfixes
and resolves the following problems:
- AudioCodes adapter registration works for first port only.
(Swyx00010542, Hotfix 13)
- Server generates access violation if transfer destination picks up call five
seconds after ip600 initiated call transfer.
(Swyx00009985, Hotfix
12)
- During endurance test all clients are logged off by SwyxServer (dead
clients).
(Swyx00010459, Hotfix 12)
- PhoneManager throws access violation on clearing the caller
list.
(Swyx00010460, Hotfix 12)
- After reset of AudioCodes TA the user(s) are registered more than once and
user(s) can not be called.
(Swyx00010461, Hotfix 12)
- Call list shows "not accepted" instead of "Redirected to
voicemail".
(Swyx00008601, Hotfix 11)
- Script postprocessing should be "busy" if voicemail is not setup for the
user.
(Swyx00009394, Hotfix 11)
- LED 2 of SX2 QuadBRI is blinking red when board works together with SX2
SinglePRI.
(Swyx00009730, Hotfix 11)
- After system uptime of 49.7 days timers can hang and cause various
problems.
(Swyx00009799, Hotfix 11)
- IpPbxGate triggers PLCI timeout during disconnect too
early.
(Swyx00009883, Hotfix 11)
- Wrong user-status (busy instead of free) after disconnecting a transfered
call.
(Swyx00009911, Hotfix 11)
- Applies to HST Saphir V ISDN board ONLY: SwyxFax Server v1.x does not
receive incoming calls if SwyxGate service is started.
NOTE: resolution
requires a HST Saphir V driver version 2.7.7.192 or higher!
(Swyx00009634,
Hotfix 11)
- Call Transfer to script sometimes not not working.
(Swyx00009370, Hotfix
10)
- Fax calls may use LCR provider which do not support fax.
(Swyx00009343,
Hotfix 10)
- Some numbers cannot be dialed because the dialnumber gets malformed through
canonicalization
(Swyx00008474, Hotfix 10)
- Improved robustness of H.323 registration between SwyxGate and
SwyxServer.
(Hotfix 10)
- Incoming call to a T.30 destination does not cause increase of buffers on
both calls.
(Swyx00008797, Hotfix 9)
- SwyxGate does not increase buffers in case of outgoing T.30
call.
(Swyx00009058, Hotfix 9)
- 'No NCCI available' in SwyxGate log in case of timed out in 'Alerting' state
on external gateway calls.
(Swyx00009096, Hotfix 9)
- 'No NCCI available' in SwyxGate log after some calls to unallocated number
from Sub-PBX.
(Swyx00009155, Hotfix 9)
- SwyxServer handles ip600 dect base station as normal H.323
device.
(Swyx00009108, Hotfix 9)
- Server throws access violation if calendar access query failed by long
timeout.
(Swyx00009139, Hotfix 9)
- Asynchronous handling of errors if Microsoft DCOM subsystem did disconnect
COM connection.
(Workaround 3, Hotfix 9)
- ONLY applies to HST Saphir V-ISDN board with driver version >= v2.7.7.x.
Since this driver version it is possible to preselect the B channel protocol
during SwyxGate service startup. This will prevent a possible switch between
different B channel protocols during call setup, which might cause the B channel
not to deliver voice data.
(Workaround 4, Hotfix 9)
- Call Cancel removes call from SwyxWare Administration but call is still
active.
(Swyx00008581, Hotfix 8)
- Number Replacement does not work correctly when overlapped sending is
used.
(Swyx00008584, Hotfix 8)
- WaitForDisconnect never returns after call transfer.
(Swyx00008860,
Hotfix 8)
- SwyxServer crashes when SwyxPhone white list is too long.
(Swyx00008878,
Hotfix 8)
- Callrouting not continued on call after redirection to switched off DECT
handset.
(Swyx00008943, Hotfix 8)
- Cancel call during call establishment to gateway forces server to unregister
gateway.
(Swyx00008971, Hotfix 8)
- Group calls ring forever on multi cell DECT ip1500.
(Swyx00008974, Hotfix
8)
- ConnectTo timeout is ignored if ip600 sends Release Complete message with
reason 'No user responding'.
(Swyx00008984, Hotfix 8)
- ConferenceMgr throws access violation on late call
details.
(Swyx00008990, Hotfix 8)
- SwyxServer service not restarted by watchdog if script file cache mutex is
blocked.
(Swyx00008742, Hotfix 7)
- SwyxServer breakdown in case of blind call transfer initiated by H.323
device. This problem occured in connection with the IP600.
(Swyx00008777,
Hotfix 7)
- Configuration changes for H.323 clients (e.g. IP600) made by SwyxWare
administration are only applied after logoff and
reregistration.
(Swyx00001321, Hotfix 7)
- SwyxServer checks during client login if that client can be reached on TCP
Port 135 (RPC endpoint mapper). The login fails if not. Without connectivity on
port 135 DCOM won't work at all. If a client with blocked port 135 connects to a
server, Microsoft's DCOM subsystem may stall on the server.
(Workaround 1,
Hotfix 7)
- PhoneManager and SwyxIt! clients poll SwyxServer during a call to keep
Microsoft DCOM subsystem from disconnecting COM connection. This ensures all
calls being disconnected properly.
(Workaround 2, Hotfix 7)
- Contains new firmware 2.1.11 for SwyxPhones L400, L420e,
L420s and L440.
(Hotfix 6)
- Please note that there is a hotfix for the IP600 DECT
system available, fixing stability problems:
- SwyxGate generates access violation during connect/disconnect stress
test.
(Swyx00008634, Hotfix 6)
- Unexpected 'CallProceeding' message sent to H.323 endpoint while
disconnecting call.
(Swyx00008656, Hotfix 6)
- Script loading sometimes fails with signature verification
error.
(Swyx00008657, Hotfix 6)
- PhoneManager threw access violation in a special scenario.
(Swyx00008680,
Hotfix 6)
- PhoneManager throws access violation on dialing a line that was hooked off
by CTI client.
(Swyx00008685, Hotfix 6)
- No caller list entry if all group members are busy or rejects the incoming
group call.
(Swyx00006829, Hotfix 5)
- Dialing public line access only is resolved to "Operator" in redial
list.
(Swyx00007863, Hotfix 5)
- Server restarted by watchdog after 'hanging' call was cancled via
admin.
(Swyx00008538, Hotfix 5)
- SendEmailEx method in script does not work, if file is
attached.
(Swyx00008565, Hotfix 5)
- SwyxFax server service does not start if SwyxFax user has more than 127
extensions.
(Swyx00008587, Hotfix 5)
- SwyxServer v4.33 does not accept v4.4x server or user upgrade
keys.
(Swyx00008623, Hotfix 5)
- Delayed call forwarding must not check if user is logged
in.
(Swyx00008347, Hotfix 4)
- Phonecall list entry state is "Call accepted" but call was diverted to
voicemail.
(Swyx00008384, Hotfix 4)
- Wrong call signalling if call to user which is busy is disconnected very
fast.
(Swyx00008419, Hotfix 4)
- Occasionally gateway service creates mini dump on SMP
system.
(Swyx00008437, Hotfix 4)
- IVR remote control via DTMF not possible if outgoing gateway call is not in
state CONNECTED.
(Swyx00008439, Hotfix 4)
- Gateway generates access violation during stress test in case of connection
termination.
(Swyx00008446, Hotfix 4)
- FollowMe action with "Start Voicemail using the # key" enabled: call is
canceled after pressing "#" if destination call is in "alerting"
state
(Swyx00008451, Hotfix 4)
- IpPbxSrv mini dump generated while VoxBox play work item.
(Swyx00008457,
Hotfix 4)
- Custom alerting sound played although script block already
left.
(Swyx00008364, Hotfix 3)
- It's not possible to log on a SwyxIt! Client when using a local (non-domain)
service account for SwyxServer. This problem was introduced with
hotfix 2 !
(Swyx00008372, Hotfix 3)
- No mediastreaming in script after "connect to" with custom alert
sound.
(Swyx00008387, Hotfix 3)
- UK analoge line break detection does not work with PIKA.
(Swyx00008400,
Hotfix 3)
- Calls may not be disconnected if LinkMgr sends H.225 Progress message on
third party links.
(Swyx00008227 - Hotfix 2)
- SwyxServer checks during client login if that client can be reached on TCP
Port 135 (RPC endpoint mapper). The login fails if not. Without connectivity on
port 135 DCOM won't work at all. If a client with blocked port 135 connects to a
server, Microsoft's DCOM subsystem may stall on the server.
(Workaround -
Hotfix 2)
- SwyxGate service didn't stop.
(Swyx00007722 - Hotfix 1)
- No early tones if SwyxLink call is routed through remote
SwyxGate.
(Swyx00008071 - Hotfix 1)
- The Speaker does not always work with L420e.
(Swyx00008078 - Hotfix
1)
- It's not possbile to send DTMF tones after pressing a single * or
#.
(Swyx00008083 - Hotfix 1)
- Changing the alert sound within a "ConnectTo" block will lead to ignoring
the configured timeout.
(Swyx00008103 - Hotfix 1)
- Switching to handfree mode during a call terminates this
call.
(Swyx00008110 - Hotfix 1)
- No more gateway calls are possible after automatic restart of IpPbxGate
service.
(Swyx00008111 - Hotfix 1)
- 'NoExtensionTimeout' does not work as expected.
(Swyx00008161 - Hotfix
1)
Further informations and a detailed installation instruction can be
found in the included README.TXT file.
ReferencesLinks
The third-party contact information included in this article is provided to help you find the technical support you need. This contact information is subject to change without notice. Swyx in no way guarantees the accuracy of this third-party contact information nor is responsible for it's content.
Updates
Created: 25.01.2006